Model No. MCU-500LS MCU-1000LS MCU-1500LS MCU-2000LS MCU-3000LS
Rated Power 300W 600W 900W 1200W 2400W
INPUT Voltage 140V---275VAC
Frequency 45--65Hz
OUTPUT Voltage 220V ±3﹪(Inverter Mode) / 220V±10﹪(Utility Mode)
Frequency 50/60±0.05Hz (Automaitc transfer according to 
the frequency of utility power )
Waveform Sine Wave
Utility Power Utility Mode with AVR Function
Cold Start Power 100% of Rated Power (for 220V Lamp)
BATTERY Type Sealed Lead-Acid, Maintenance-free
DC Voltage 12VDC 24VDC 48VDC
Capacity Depending on the external battery
Back-up Time
(Half/Full Load)
Value of Low 
Voltage Protection
11V+/-0.2V 22V+/-0.5V 42V+/-0.5V
Value for Under 
Voltage Protection
10V+/-0.2V 21V+/-0.5V 41V+/-0.5V
Charging Voltage 13.8V+/-0.2V 28V+/-0.5V 55.5V+/-0.5V
Charging Current 8.0-10A 10-15A 10-15A 15-20A 15-20A
Recharge Time ≤8Hours.Charging up to 90%
Reverse Connection No startup, no damage to the UPS
Charging Mode Automatic charging while power off & accessing to utility power
Transfer Time < 5ms < 5ms < 5ms < 5ms < 5ms
AUDIBLE 
ALARM
Utility Power Normal No alarm
Battery Discharge Beeping sound every 30 seconds 
after utility power fails
Beeping sound every 30 seconds after utility power fails.
Keep pressing the Silent Function Button 
for 2 seconds for muteness.
Beeping sound every second for low voltage alarm
Fault Turn to Battery Mode without output, 
continiuous beep for 20 seconds then automatically shutdown
PROTECTION Overload 
Protection
Battery Mode: Overload 125%: continuous beeping, cut down the output 
after 30 seconds & shutdown after another 20 seconds.
Overload above 150%: immediate protecting. /
Utility Mode: continuous beeping without protection. 
Low Voltage 
Protection
Automatically shutdown, return to normal mode 
after utility power accessed
High Tempreture 
Protection
Turn to Battery Mode, 
shutdown while Inner tempreture be up to 90℃
Short Curcuit 
Protection
Automatically cut down the output & shutdown after 20 seconds
On/Off Mode ON: Keep pressing the On-off button for 2 seconds for startup.
Automatically start without pressing the ON button 
while accessing to utility power.  
OFF: Keep pressing the On-off button for 2 seconds for shutdown.
Battery be charged normally with UPS cutting down the output 
while accessing to utility power.
Cooling System Thermostatic Control Fan
Indicators LCD
COMMUNI-CATION Port Rs232/USB
Interface Monitor of Utility Fault,Power Failure,
Battery,UPS Statu Indicator etc.
Software Function 1.Anlysis of Power Status, 2.Timing Controlling, 
3.Monitor UPS, 4.Execute UPS Self-diagnosis, 5.Automatic Save
Noise(dB) < 35dB < 40dB < 45dB
Operating Temperature 0℃~40℃
Relative Humidity 20% ~ 90% non-condensing
Dimension(mm) 155*85*360 195*120*320 145*435*220 192*490*340 192*490*340
Net Weight(Kg) 5.00  7.50  12.00  21.50  26.50